Multi-Lyte Direct/Indirect 2-Light T8 or T5
Performance
Report Number
: LRL797-3C
Lamps
: 2-F32T8/TL80
Lumens
: 3050
IES Spacing Criterion
:5
-Max S/MH
:PARA:5,PERP:5
BF
= 1.0
125
90 70
% Effective Ceiling
Cavity Reflectance
50 1 30 10
0
115
50 3010 50 3010
%WallRef
50 30 10
ectance
50 3010 50 30 10 0
0
96 96 96 80 80 80 66 66 66 53 53 53 40 40 40 35
105 1
85 82 79 71 69 67 59 57 56 48 47 46 37 37 36 31
2
76 70 66 64 60 57 53 51 48 44 42 40 34 33 32 28
95 3
67 61 56 57 53 49 48 45 42 40 37 36 32 30 29 26
90
85 ^
60 53 48 51 46 42 43 40 37 36 33 31 29 27 26 23
5
54 47 41 46 41 37 39 35 32 32 29 27 26 24 23 20
75 6
48 41 36 41 36 32 35 31 28 29 26 24 24 22 20 18
7
43 36 31 37 32 28 31 27 24 26 23 21 21 19 18 15
65 8
39 32 27 33 28 24 28 24 21 24 20 18 19 17 15 13
9
35 28 24 30 25 21 26 21 18 21 1816 17 15 13 12
55 10
31 24 20 26 21 18 22 18 15 19 15 13 15 13 11 9
Candle Power Summary
Zone 0 22 45 67 90
Deg. Candelas
180 738 738 738 738 738
175 740 744 745 756 754
165 728 752 783 819 840
155 669 724 789 846 856
145 594 684 772 816 825
135 474 589 656 727 754
125 380 498 600 720 767
115 238 350 532 602 601
105 127 258 320 300 290
95 33 67 51 47 44
90 0 4 8 8 10
85 2 3 4 6 6
75 6 9 11 14 13
65 24 33 49 79 66
55 85 179 356 531 592
45 307 542 758 888 919
35 488 640 889 1172 1226
25 585 644 766 991 1041
15 657 674 704 762 789
5 677 682 682 679 686
0 678 678 678 678 678
Zonal Lumens and Percentages
Zone .umens % Barelamps % Luminaires
0-90 2128 84.8 41.6
90-180 2976 48.8 58.4
0-180 5099 88.6 100.0
Footcandles
Channel Luminaire Luminaire
Spacing
O.C.
Spacing
O.C.
Suspension
18" 24"
5' 167 166
O' O' 112 111
8' 84 83
5' 100 99
8' O' 84 83
8' 63 02
5' 80 79
10 6' 67 66
8' 50 50
Suspension Mounting Detail
Footcandles are average, initial, include a
ballast factor of 0.87 and are at a work plane
height of 30" above fhefloor.The luminaires are
suspended 8' above fhefloorin a 50'x70' room
(ceiling height is 8' plus luminaire suspension.)
Room reflectances are: 80% ceiling, 50% walls
and20%floor.
Module Dimensions Detail
25-5/8‘
K|65.09cm|-H
|46.83cm|
Fixture Mounting Detail
16'(40.64cm)
K 25-l/2'^
|64.77cm|
- 49-5/8'|126.05cm| -
1
18-7/16'
\<
- - - - - -
41-13/16'
- - - - - - - - -
*\
|196.29cm|
t^39'|76.29cm|-
-49-l/2'|125.73cm|-
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C1008
PHILIPS
Zobrazit stránku 1
1 2

Komentáře k této Příručce

Žádné komentáře